Dry Sterilizer (Laboratory use) (SK811)
Dry heat sterilization with independent overheat prevention device
Features of Dry Sterilizer (Laboratory use) (SK811)
- Programmable
- High precision controller with improved display visibility and operability
- Standard equipped with calibration offset, lock function, power recovery mode, power on and operation time accumulation, calendar time, accumulation power consumption monitoring, total CO2 emission, and heat output, save and access operator setting information
- Maximum 99 steps, 99 patterns, repeat operation
-
Easy sample data collection with cable port
Safety features
Standard equipped with self diagnostic functions, independent overheat prevention device and earth leakage breaker
Specifications
Specifications
Item Code | 212912 |
---|---|
Model | SK811 |
Circulation method | Natural convection |
Temp. setting range | Room temp. +5~210°C |
Temp. control accuracy | ±1¡æ£¨at 210¡æ£©JTM K05/±1.5¡æ£¨at 210¡æ£©JIS |
Temp. fluctuation | ±5¡æ£¨at 210¡æ£©JTM K05/20¡æ£¨at 210¡æ£©JIS |
Temp. rising time | Approx. 60min. |
Interior / Exterior material | Stainless Steel / Chrome free electrogalvanized carbon steel sheet coated with chemical-proof baked-on finish |
Insulation Material | Glass wool |
Heater | SUS 2.4kW |
Sensor | K type Thermocouple |
Fan type / Fan motor | Sirocco Fan / Condenser type motor 30W |
Cable port | I.D. 33mm (right side) |
Exhaust port | I.D. 33mm×2 (back side) |
Temperature control | PID control by microprocessor |
Temperature display | Temp. display: Green 4-digit LED digital display (increment: 1°C) |
Timer | 0 min~99 hrs 59 min (increment: 1 min. or 1 hr.) |
Heater control | Triac with Zero-cross control |
Operation function | Fixed temperature, Auto start, Auto stop, Quick auto stop, Program (99 steps, 99 patterns, Repeat operation function) |
Additional function | Power on and operation time accumulation function (up to 65535 hours), Calendar time (24 hours), Calibration offset, |
Safety device | Self-diagnostic functions (Sensor failure, SSR short circuit, Heater failure, Main relay contact failure, Automatic overheat prevention), |
Internal dimensions£¨W×D×H mm£© | 600×500×1000mm |
External dimensions£¨W×D×H mm£© | 710×650×1640mm |
Remarks(dimensions) | Internal capacity¡¡300L |
Power Source |
AC200V 12.5A Breaker capacity¡¡15A |
Weight | 108kg |
Maintenance and warranty
Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
External dimensions do not include protrusions.