Incubator (Natural Convection, Air Jacket) (IS401)
Incubators of natural convection by air-jacket, equipped with various functions
Features of Incubator (Natural Convection, Air Jacket) (IS401)
- Air Jacket and Natural Convection Incubator
- Air Jacket and Natural Convection, Fix temperature opration, Quick auto stop, Auto stop, Auto start operation are available
- 3 patterns, 30 steps programming are available
- The air-jacket method makes it possible to obtain uniform temperature distribution
- Sample can be observed through the inner door
- Equipped with self-diagnosis function, a key-lock function and an over-current breaker
- Possible to place the models IS401/601 in piles, one over the other
- Various expanded function due to external communication function, temperature output terminal
- The operation before power failure can be resumed
Specifications
| Item Code | 212551 |
|---|---|
| Model | IS401 |
| Type | Air Jacket Type, Natural Convection |
| Temperature Range | Room Temp. +5¡«80¡æ |
| Temp. Adjustment Accuracy | ±0.5¡æ at 37¡æ |
| Temp. Distribution Accuracy | ±1.0¡æ at 37¡æ |
| Interior | Stainless Steel |
| Exterior | Cold Rolled Steel Plate with Chemical-resistant Coating |
| Insulation Material | Glass Wool |
| Heater | Iron-chrome Wire Heater |
| Exhaust Port | 30mm ID x 2 (on the top) |
| Temp. Setting Method | Digital Setting by ¨‹¡ø Key |
| Temp. Display | Digital Display by LED |
| Timer | 1 to 99hrs 59min. and 100 to 999 hrs |
| Program Mode | Program Operation 3 patterns, 30 steps, Pattern Repeat Function |
| Additional Function | Calibration Offset Function, Key-lock Function, Blackout Recovery Function |
| Safety Device | Self Diagnostic Function£¨Automatic Overheat Prevention, Abnormal Temp. Sensor, Heater Disconnection, SSR Short Circuit, Main Relay Error£©, Overheat Preventor, Overcurrent ELB, Key-lock Function, Door Key, Adjuster£¨812/912£© |
| Shelf Loading Capacity | Approx. 15kg/shelf |
| Shelf support step number/Pitch | Max. 11 steps / 30mm |
| Shelf/ Support | 2 shelves/ 4 supports |
| Time required to reach 60¡æ | Approx. 70 min. |
| Inner Glass Window | Reinforced Glass 5mm t |
| Temp. Controller | PID control by microprocessor |
| Min. Timer Division | 1min. or 10min. |
| Operation Function | Fixed Temp., Program Operation, Quick Auto-stop Operation, Auto-stop Operation, Auto-start Operation |
| Heater Circuit Control | SSR Drive |
| Temp. Sensor | Pt. Thermal Resistance Pt100Ω£¨Temp. Adjuster£©, K-Thermcouple£¨Overheat Preventor£© |
| Internal dimensions£¨W×D×H mm£© | 450×480×450mm |
| External dimensions£¨W×D×H mm£© | 560×606×820mm |
| Remarks(dimensions) | 97L |
| Power Source |
AC220V 1.5A Single phase |
| Weight | 55kg |
Maintenance and warranty
Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
External dimensions do not include protrusions.