Standard Electric Furnace (FO610)
8 types of internal capacity are available, with program operation function
Features of Standard Electric Furnace (FO610)
- Able to do program operation
- Easier up/down key setting, equipped with the controller ofgood operation performance to realize the high precision of temp. control.
- Digital representation of setting temp., time and indicator value.
- Use the controller of digital set and overheat proection, in the event of abnormality it has safety controls such as self diagnosis and overcurrent ELB.
- The temp. sensor applies R-thermocouple with long service life.
- Equipped with exhaust port.
- It also has optional functions like air exhaust device, sample tray, N2 introduction device (attached with flowmeter), temp. output terminal, etc..
Specifications
| Item Code | 214121 |
|---|---|
| Model | FO610 |
| Operating temp. range | 100 to 1,150¡æ |
| Temp. control accuracy | ±2.0¡æ£¨at 1,150¡æ£© |
| Max. temp. reaching time | Approx. 80min. |
| Exterior material | Cold rolled steel plate with baked-on melamine resin finish |
| Internal material | Ceramic fiber |
| Sensor | R-thermocouple |
| Heater | Iron-chrome wire |
| Heater | 3kW |
| Exhaust port | 18 mm I.D. (upper part) |
| Cooling Fan Type | Axial fan motor |
| Temp. controller | PID control by microprocessor |
| Temp. setting/display method | Digital setting by¡ø/¨‹ keys / Digital display |
| Overheat protection | Integrated controller |
| Overheat protection set | Digital setting |
| Operation function | Fixed temp., program (6 modes 30 seg.×1, 15 seg.×2, 10 seg.×3) |
| Additional function | Deviation correction, Power outage compensation, Key lock |
| Timer | 1min to 99hr59min and 999hr 50min digital setting, Auto start, Quick auto stop |
| Safe Device | Self diagnosis circuit (Abnormal temp. sensor, Auto overheat protection), Averheat protector, Avercurrent ELB, key lock |
| Accessories | Exhaust port cap 1 pc. |
| Optional Stand | ON61C |
| Optional Others | Exhaust device (AC220V), Sample tray, N2 introduction device (Attached with flow meter), Recorder, Indicator lamp (Stand-by / running / Malfunction), |
| Optional Others | External communication (RS485), Temp. output terminal (4-20mA), Output terminal for alarm device, Time up output terminal |
| Internal dimensions£¨W×D×H mm£© | 250×350×200mm |
| External dimensions£¨W×D×H mm£© | 507×604×677mm |
| Remarks(dimensions) | 17.5L |
| Power Source |
AC220V 15A Single-phase |
| Weight | 52kg |
Maintenance and warranty
Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
External dimensions do not include protrusions.