Spray Dryer Pulvis Mini Bed (GB210-B)
Spray dryer capable of granulating and drying wet powder.
Features of Spray Dryer Pulvis Mini Bed (GB210-B)
- Designed to granulate powder and dry wet powder using a fluid bed. This is a fluid bed drying granulator used in combination with the basic unit GB210 and Mini-bed attachment GF200.
- The chamber is made of ultra hard glass and the user can observe status of the fluid bed or spraying status. Also, the flowage meter, the spraying pressure
- meter, the chamber inlet/outlet temperature indicator are useful for evaluation of data
- The unit can also be used as a spraying dryer by installing the mini spray attachment GF300 (optional)
- The unit has an automatic lift as a standard to enable convenient installation or removal of the glass chamber attachment
Control Panel
Inlet temperature, outlet temperature, and drying air amount are digitally displayed. Setting is made on the touch panel that allows operation settings, operation status display as well as error display, and settings of various operation conditions.
Specifications
Item Code | 212778 |
---|---|
Model | GB210-B |
Temp. adjusting unit setting range | 40 to 220°C (inlet temperature), 0 to 98°C (Outlet temperature) |
Temperature adjusting accuracy | Inlet temperature ± 1°C |
Spraying system | Two-way nozzle, Nozzle No. 1A as standard |
Drying air amount adjusting range | 0 to 0.7m3/min |
Spray air pressure adjusting range | 0 to 0.3MPa |
Liquid sending pump flow rate range | 0 to 26mL/min |
Spray air pressure adjusting range | 0 to 0.3MPa |
Liquid sending pump flow rate range | 0 to 26 mL/min |
External output | Inlet temperature, Outlet temperature, Temperature outlet (4-20 mA) |
Automatic lift | Moving up/down of glass chamber automatic lift |
Temperature adjusting device | PID digital temperature adjusting device |
Touch panel | Blower, Heater, Liquid sending pump, Pulse jet switch, Error display |
Control select switch | Inlet temperature, Output temperature control switch (Outlet temp. control is conditional) |
Temperature sensor | K-thermocouple |
Heater | 2.0kW (at200V) to 2.88kW (at240V) |
Liquid sending pump | Fixed amount peristaltic pump |
Spraying air pump | Spraying air compressor (Sold separately) is used |
Service outlet | For stirrer: AC100V, Max. 2A |
Suction blower | Bypass blower, Brushless DC motor |
Filter | Suction filter, Exhaust filter |
Recovery of solvent | Solvent recovery unit GAS410 (Sold separately) is used |
Spray nozzle cooling mechanism | Connector: nipple×2, O.D.: ø10.5mm |
Spray air connection diameter | Nipple diameter: ø7mm |
Exhaust connecting diameter | ø50mm |
Exhaust connecting diameter | ø50mm |
Safety device | Inlet/Outlet temperature overheat, Sample feed reverse rotation mechanism, Over current electric leakage breaker, Nozzle connection error |
Accessories | Silicon tube (with a stopper)×3, Tiron tube (with a stopper)×2, Exhaust duct (with one hose band)×1, Outlet temperature sensor, Spray air tube, Sample box, Static electricity removal earth, Teflon braided hose 5m (with two hose bands), Container table |
External dimensions£¨W×D×H mm£© | 760×420×1350mm |
Power Source |
AC220V 17A Single phase |
Weight | 110kg |
Maintenance and warranty
Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
External dimensions do not include protrusions.